Line Conditioners

Our pick

Eaton Tripp Lite LC1800

Choose the Eaton Tripp Lite LC1800 for a compatible 120V workstation: its six outlets, seven-foot cord and explicit 1,440W continuous rating give you a clear load and placement limit.1

Why this one

  • Its automatic voltage regulation covers the stated 89V to 147V input range; match your equipment and supply, and keep the combined continuous load within 1,440W.1
Compare the alternatives

The alternatives

Other contenders

  • Eaton Tripp Lite LC2400

    Choose the LC2400 for its 1,920W continuous rating only when the installation meets the maker’s 120V, 20A circuit requirements; its included wireable 5-20P option is separate from the attached 5-15P plug.2

  • Eaton Tripp Lite LS606M

    Choose the LS606M for a smaller setup that fits its stated 600W capacity when moving and placing a 3.8lb unit matters more than the LC1800’s higher continuous rating.13

Compare the options

3 products

Compare models side by side

Models in this comparison

Every specification for these products
SpecificationEaton Tripp Lite LC1800Eaton Tripp Lite LC2400Eaton Tripp Lite LS606M
Nominal input voltage120 V1120 V2120 V3
Input frequency60 Hz160 Hz260 Hz3
Input plugNEMA 5-15P1NEMA 5-15P Input Cord Details Optional wireable 5-20P input plug is included for use with 120V 20A circuit applications2NEMA 5-15P3
Output outlet inventory(6) 5-15R1(2) 5-15/20R; (4) 5-15R2(6) 5-15R3
Load rating descriptionAgency de-rated per NFPA 70 to 12A, 1440W continuous and up to 15A, 1800W intermittent1Load Capacity (Watt) 2.40 kW4Output (Watts) 6003
Continuous output1,440 W (Duration: continuous)11,920 W (Duration: continuously; Tested configuration: 120V 20A rated circuit)2Not published
Cord length7 ft16 ft26 ft3
Unit weight9.6 lb111.2 lb23.8 lb3
Unit dimensionsUnit Dimensions (hwd / in.) 7.000 x 6.000 x 7.0001Unit Dimensions (hwd / in.) 7.000 x 6.000 x 9.5002Unit Dimensions (hwd / in.) 5.500 x 4.750 x 4.7503
Voltage correctionMaintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.1Maintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.2Maintains usable 120V nominal output to sensitive electronics during severe brownouts and overvoltages. Overvoltage Correction Input voltages over 128V (+/-3V) are reduced by 10.6% Undervoltage Correction Input voltages between 111V (+/-3V) and 103V (+/-3V) are boosted by 13.4%.3

How they compare

Scroll the table to see every product and specification.

SpecificationOur pickEaton Tripp Lite LC1800Eaton Tripp Lite LC2400Eaton Tripp Lite LS606M
Nominal input voltage120 V1120 V2120 V3
Input frequency60 Hz160 Hz260 Hz3
Input plugNEMA 5-15P1NEMA 5-15P Input Cord Details Optional wireable 5-20P input plug is included for use with 120V 20A circuit applications2NEMA 5-15P3
Output outlet inventory(6) 5-15R1(2) 5-15/20R; (4) 5-15R2(6) 5-15R3
Load rating descriptionAgency de-rated per NFPA 70 to 12A, 1440W continuous and up to 15A, 1800W intermittent1Load Capacity (Watt) 2.40 kW4Output (Watts) 6003
Continuous output1,440 W (Duration: continuous)11,920 W (Duration: continuously; Tested configuration: 120V 20A rated circuit)2Not published
Cord length7 ft16 ft26 ft3
Unit weight9.6 lb111.2 lb23.8 lb3
Unit dimensionsUnit Dimensions (hwd / in.) 7.000 x 6.000 x 7.0001Unit Dimensions (hwd / in.) 7.000 x 6.000 x 9.5002Unit Dimensions (hwd / in.) 5.500 x 4.750 x 4.7503
Voltage correctionMaintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.1Maintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.2Maintains usable 120V nominal output to sensitive electronics during severe brownouts and overvoltages. Overvoltage Correction Input voltages over 128V (+/-3V) are reduced by 10.6% Undervoltage Correction Input voltages between 111V (+/-3V) and 103V (+/-3V) are boosted by 13.4%.3