Buying guide
Line Conditioners
Our pick
Eaton Tripp Lite LC1800
Choose the Eaton Tripp Lite LC1800 for a compatible 120V workstation: its six outlets, seven-foot cord and explicit 1,440W continuous rating give you a clear load and placement limit.1
Why this one
- Its automatic voltage regulation covers the stated 89V to 147V input range; match your equipment and supply, and keep the combined continuous load within 1,440W.1
The alternatives
Other contenders
Choose the LC2400 for its 1,920W continuous rating only when the installation meets the maker’s 120V, 20A circuit requirements; its included wireable 5-20P option is separate from the attached 5-15P plug.2
Choose the LS606M for a smaller setup that fits its stated 600W capacity when moving and placing a 3.8lb unit matters more than the LC1800’s higher continuous rating.13
Compare the options
3 products
Product image unavailableEaton Tripp Lite LC1800
Product image unavailableEaton Tripp Lite LC2400
Product image unavailableEaton Tripp Lite LS606M
Compare models side by side
Choose two or three products to compare.
Models in this comparison
Every specification for these products
| Specification | Eaton Tripp Lite LC1800 | Eaton Tripp Lite LC2400 | Eaton Tripp Lite LS606M |
|---|---|---|---|
| Nominal input voltage | 120 V1 | 120 V2 | 120 V3 |
| Input frequency | 60 Hz1 | 60 Hz2 | 60 Hz3 |
| Input plug | NEMA 5-15P1 | NEMA 5-15P Input Cord Details Optional wireable 5-20P input plug is included for use with 120V 20A circuit applications2 | NEMA 5-15P3 |
| Output outlet inventory | (6) 5-15R1 | (2) 5-15/20R; (4) 5-15R2 | (6) 5-15R3 |
| Load rating description | Agency de-rated per NFPA 70 to 12A, 1440W continuous and up to 15A, 1800W intermittent1 | Load Capacity (Watt) 2.40 kW4 | Output (Watts) 6003 |
| Continuous output | 1,440 W (Duration: continuous)1 | 1,920 W (Duration: continuously; Tested configuration: 120V 20A rated circuit)2 | Not published |
| Cord length | 7 ft1 | 6 ft2 | 6 ft3 |
| Unit weight | 9.6 lb1 | 11.2 lb2 | 3.8 lb3 |
| Unit dimensions | Unit Dimensions (hwd / in.) 7.000 x 6.000 x 7.0001 | Unit Dimensions (hwd / in.) 7.000 x 6.000 x 9.5002 | Unit Dimensions (hwd / in.) 5.500 x 4.750 x 4.7503 |
| Voltage correction | Maintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.1 | Maintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.2 | Maintains usable 120V nominal output to sensitive electronics during severe brownouts and overvoltages. Overvoltage Correction Input voltages over 128V (+/-3V) are reduced by 10.6% Undervoltage Correction Input voltages between 111V (+/-3V) and 103V (+/-3V) are boosted by 13.4%.3 |
How they compare
Scroll the table to see every product and specification.
| Specification | Our pickEaton Tripp Lite LC1800 | Eaton Tripp Lite LC2400 | Eaton Tripp Lite LS606M |
|---|---|---|---|
| Nominal input voltage | 120 V1 | 120 V2 | 120 V3 |
| Input frequency | 60 Hz1 | 60 Hz2 | 60 Hz3 |
| Input plug | NEMA 5-15P1 | NEMA 5-15P Input Cord Details Optional wireable 5-20P input plug is included for use with 120V 20A circuit applications2 | NEMA 5-15P3 |
| Output outlet inventory | (6) 5-15R1 | (2) 5-15/20R; (4) 5-15R2 | (6) 5-15R3 |
| Load rating description | Agency de-rated per NFPA 70 to 12A, 1440W continuous and up to 15A, 1800W intermittent1 | Load Capacity (Watt) 2.40 kW4 | Output (Watts) 6003 |
| Continuous output | 1,440 W (Duration: continuous)1 | 1,920 W (Duration: continuously; Tested configuration: 120V 20A rated circuit)2 | Not published |
| Cord length | 7 ft1 | 6 ft2 | 6 ft3 |
| Unit weight | 9.6 lb1 | 11.2 lb2 | 3.8 lb3 |
| Unit dimensions | Unit Dimensions (hwd / in.) 7.000 x 6.000 x 7.0001 | Unit Dimensions (hwd / in.) 7.000 x 6.000 x 9.5002 | Unit Dimensions (hwd / in.) 5.500 x 4.750 x 4.7503 |
| Voltage correction | Maintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.1 | Maintains usable 120V nominal voltage during brownouts as low as 89VAC and over-voltages as high as 147VAC. Input voltages between 112V~127V are passed through unchanged.2 | Maintains usable 120V nominal output to sensitive electronics during severe brownouts and overvoltages. Overvoltage Correction Input voltages over 128V (+/-3V) are reduced by 10.6% Undervoltage Correction Input voltages between 111V (+/-3V) and 103V (+/-3V) are boosted by 13.4%.3 |