Buying guide
Line-Interactive UPS Systems
Our pick
CyberPower CP1000PFCLCDA
Choose the CyberPower CP1000PFCLCDA for a computer setup within 600W that needs pure sine-wave battery power.1
Why this one
- Five battery-backed outlets cover a computer and essential peripherals; the ten-outlet total includes sockets that will not keep equipment running through an outage.1
The alternatives
Other contenders
For a desk, shelf or spot on the floor
A tower body fits a setup without a server rack.9 The CP1500AVRLCD3 provides six backed sockets and a 900W combined limit in a mini-tower body.915
For a rack in a server room
A rack installation needs a chassis made to mount in the rack.11 The CP1500PFCRM2U occupies 2U and supplies eight backed sockets within a 1,000W load limit.1011
10 models / at a glance
Key differences
Compare the options
10 products
Narrow your options
Reset requirements10 models in this chart.
Battery-backed outlets (outlets); higher is preferred · 0 to 8
Output capacity (W); higher is preferred · 0 to 1,000
Product image unavailableCyberPower CP1000PFCLCDA
Product image unavailableAPC BR1000MS
Product image unavailableAPC BR1350MS
Product image unavailableAPC BX1000M
Product image unavailableCyberPower AVRG900LCD
Product image unavailableCyberPower CP850PFCLCDA
Product image unavailableCyberPower CP1000AVRLCD
Product image unavailableCyberPower CP1350PFCLCD
Compare models side by side
Choose two or three products to compare.
Models in this comparison


Every specification for these products
| Specification | CyberPower CP1000PFCLCDA | APC BR1000MS | APC BR1350MS | APC BX1000M | CyberPower AVRG900LCD | CyberPower CP850PFCLCDA | CyberPower CP1000AVRLCD | CyberPower CP1350PFCLCD | CyberPower CP1500AVRLCD3 | CyberPower CP1500PFCRM2U |
|---|---|---|---|---|---|---|---|---|---|---|
| Output capacity | 600 W1 | 600 W2 | 810 W3 | 600 W4 | 480 W5 | 510 W6 | 600 W7 | 880 W8 | 900 W15 | 1,000 W11 |
| Runtime at half load | 6 min (Workload: 300W (half rated load). Runtime varies with battery condition and connected load.)1 | 12.2 min (Workload: 300W (half rated load), 120V. Runtime varies with battery condition and connected load.)16 | 11.4 min (Workload: 405W (half rated load), 120V. Runtime varies with battery condition and connected load.)16 | 13.5 min (Workload: 300W (half rated load), 120V. Runtime varies with battery condition and connected load.)16 | 10 min (Workload: 240W (half rated load). Runtime varies with battery condition and connected load.)5 | 9 min (Workload: 255W (half rated load). Runtime varies with battery condition and connected load.)6 | 9 min (Workload: 300W (half rated load). Runtime varies with battery condition and connected load.)7 | 8 min (Workload: 440W (half rated load). Runtime varies with battery condition and connected load.)8 | 12 min9 | 10.2 min10 |
| Battery-backed outlets | 5 outlets1 | 6 outlets12 | 6 outlets13 | 4 outlets14 | 6 outlets5 | 5 outlets6 | 5 outlets7 | 6 outlets8 | 6 outlets15 | 8 outlets10 |
| VA rating | 1,000 VA1 | 1,000 VA2 | 1,350 VA3 | 1,000 VA4 | 900 VA5 | 850 VA6 | 1,000 VA7 | 1,350 VA8 | 1,500 VA9 | 1,500 VA10 |
| Runtime at full load | 2 min (Workload: 600W (full rated load). Runtime varies with battery condition and connected load.)1 | 3.7 min (Workload: 600W (full rated load), 120V. Runtime varies with battery condition and connected load.)16 | 3.3 min (Workload: 810W (full rated load), 120V. Runtime varies with battery condition and connected load.)16 | 4.3 min (Workload: 600W (full rated load), 120V. Runtime varies with battery condition and connected load.)16 | 2 min (Workload: 480W (full rated load). Runtime varies with battery condition and connected load.)5 | 3 min (Workload: 510W (full rated load). Runtime varies with battery condition and connected load.)6 | 2 min (Workload: 600W (full rated load). Runtime varies with battery condition and connected load.)7 | 2 min (Workload: 880W (full rated load). Runtime varies with battery condition and connected load.)8 | 3 min9 | 3.1 min10 |
| Total outlets | 10 outlets1 | 10 outlets12 | 10 outlets13 | 8 outlets14 | 12 outlets5 | 10 outlets6 | 9 outlets7 | 12 outlets8 | 12 outlets9 | 8 outlets10 |
| Output waveform | Pure sine1 | Pure sine2 | Pure sine3 | Simulated sine4 | Simulated sine5 | Pure sine6 | Simulated sine7 | Pure sine8 | Simulated sine9 | Pure sine10 |
| UPS type | Line interactive1 | Line interactive2 | Line interactive3 | Line interactive4 | Line interactive5 | Line interactive6 | Line interactive7 | Line interactive8 | — | — |
| Form factor | — | — | — | — | — | — | — | — | Tower9 | Rack mount11 |
| Rack height | — | — | — | — | — | — | — | — | — | 2 U11 |
| Input voltage | — | — | — | — | — | — | — | — | 120 V9 | 120 V10 |
Compare features
Reset requirements
10 products
Product image unavailableCyberPower CP1000PFCLCDA
Product image unavailableAPC BR1000MS
Product image unavailableAPC BR1350MS
Product image unavailableAPC BX1000M
Product image unavailableCyberPower AVRG900LCD
Product image unavailableCyberPower CP850PFCLCDA
Product image unavailableCyberPower CP1000AVRLCD
Product image unavailableCyberPower CP1350PFCLCD
How they compare
| Specification | Our pickCyberPower CP1000PFCLCDA | APC BR1000MS | APC BR1350MS | APC BX1000M | CyberPower AVRG900LCD | CyberPower CP850PFCLCDA | CyberPower CP1000AVRLCD | CyberPower CP1350PFCLCD | CyberPower CP1500AVRLCD3 | CyberPower CP1500PFCRM2U |
|---|---|---|---|---|---|---|---|---|---|---|
| Buy | ||||||||||
| Output capacity | 600 W1 | 600 W2 | 810 W3 | 600 W4 | 480 W5 | 510 W6 | 600 W7 | 880 W8 | 900 W15 | 1,000 W11 |
| Runtime at half load | 6 min (Workload: 300W (half rated load). Runtime varies with battery condition and connected load.)1 | 12.2 min (Workload: 300W (half rated load), 120V. Runtime varies with battery condition and connected load.)16 | 11.4 min (Workload: 405W (half rated load), 120V. Runtime varies with battery condition and connected load.)16 | 13.5 min (Workload: 300W (half rated load), 120V. Runtime varies with battery condition and connected load.)16 | 10 min (Workload: 240W (half rated load). Runtime varies with battery condition and connected load.)5 | 9 min (Workload: 255W (half rated load). Runtime varies with battery condition and connected load.)6 | 9 min (Workload: 300W (half rated load). Runtime varies with battery condition and connected load.)7 | 8 min (Workload: 440W (half rated load). Runtime varies with battery condition and connected load.)8 | 12 min9 | 10.2 min10 |
| Battery-backed outlets | 5 outlets1 | 6 outlets12 | 6 outlets13 | 4 outlets14 | 6 outlets5 | 5 outlets6 | 5 outlets7 | 6 outlets8 | 6 outlets15 | 8 outlets10 |
| VA rating | 1,000 VA1 | 1,000 VA2 | 1,350 VA3 | 1,000 VA4 | 900 VA5 | 850 VA6 | 1,000 VA7 | 1,350 VA8 | 1,500 VA9 | 1,500 VA10 |
| Runtime at full load | 2 min (Workload: 600W (full rated load). Runtime varies with battery condition and connected load.)1 | 3.7 min (Workload: 600W (full rated load), 120V. Runtime varies with battery condition and connected load.)16 | 3.3 min (Workload: 810W (full rated load), 120V. Runtime varies with battery condition and connected load.)16 | 4.3 min (Workload: 600W (full rated load), 120V. Runtime varies with battery condition and connected load.)16 | 2 min (Workload: 480W (full rated load). Runtime varies with battery condition and connected load.)5 | 3 min (Workload: 510W (full rated load). Runtime varies with battery condition and connected load.)6 | 2 min (Workload: 600W (full rated load). Runtime varies with battery condition and connected load.)7 | 2 min (Workload: 880W (full rated load). Runtime varies with battery condition and connected load.)8 | 3 min9 | 3.1 min10 |
| Total outlets | 10 outlets1 | 10 outlets12 | 10 outlets13 | 8 outlets14 | 12 outlets5 | 10 outlets6 | 9 outlets7 | 12 outlets8 | 12 outlets9 | 8 outlets10 |
| Output waveform | Pure sine1 | Pure sine2 | Pure sine3 | Simulated sine4 | Simulated sine5 | Pure sine6 | Simulated sine7 | Pure sine8 | Simulated sine9 | Pure sine10 |
| UPS type | Line interactive1 | Line interactive2 | Line interactive3 | Line interactive4 | Line interactive5 | Line interactive6 | Line interactive7 | Line interactive8 | — | — |
| Form factor | — | — | — | — | — | — | — | — | Tower9 | Rack mount11 |
| Rack height | — | — | — | — | — | — | — | — | — | 2 U11 |
| Input voltage | — | — | — | — | — | — | — | — | 120 V9 | 120 V10 |
Sources
- www.cyberpower.com
- cdn.blueally.com
- cdn.adiglobaldistribution.us
- inquirecontent2.ingrammicro.com
- dl4jz3rbrsfum.cloudfront.net
- www.cyberpower.com
- inquirecontent2.ingrammicro.com
- cctv.net
- dl4jz3rbrsfum.cloudfront.net
- dl4jz3rbrsfum.cloudfront.net
- www.servethehome.com
- www.amazon.com
- www.amazon.com
- www.amazon.com
- www.popularmechanics.com
- www.apcguard.com