Browse by type
The alternatives
Other contenders
For a gaming PC or workstation you need to shut down safely
A higher-load computer setup needs a UPS whose output rating covers the combined connected load.16 The desktop CP1500AVRLCD3 suits a 120V computer setup within 900W; its battery output is simulated sine wave, so check the equipment’s waveform requirement.24
For a router, modem and network gear
Count the network devices that need battery-backed sockets and check their combined load.12 The BE600M1 gives a 120V setup five backed sockets and a 330W output limit.12
For power supplies that need pure sine-wave power
Equipment with a sine-wave requirement needs that waveform while the UPS runs on its battery.5 The 2U rack-mount CP1500PFCRM2U supplies sine-wave battery output within a 1,000W combined load limit.56
For keeping several devices on battery
Count battery-backed sockets separately from the total AC outlet count.28 All eight AC sockets on the 2U rack-mount CP1500PFCRM2U are battery-backed, for equipment within its 1,000W total limit.56
6 models / at a glance
Key differences
Compare the options
6 products
Narrow your options
Reset requirements6 models compared.
Battery-backed outlets (outlets); higher is preferred · 0 to 8
Output capacity (W); higher is preferred · 0 to 1,350
Compare models side by side
Choose two or three products to compare.
Models in this comparison





Every specification for these products
| Specification | APC BE600M1 | APC Back-UPS ES-BE700G | APC Smart-UPS SRT1500XLA | CyberPower CP1500AVRLCD3 | CyberPower CP1500PFCRM2U | Eaton 9SX1500 |
|---|---|---|---|---|---|---|
| Output capacity | 330 W1 | 405 W8 | 1,350 W3 | 900 W2 | 1,000 W6 | 1,350 W7 |
| Runtime at half load | 10 min8 | 13 min8 | Approx. 14 min (Workload: half load)11 | 12 min4 | 10.2 min5 | 16.5 min (Workload: 675W)7 |
| Battery-backed outlets | 5 outlets2 | 4 outlets9 | 6 outlets10 | 6 outlets2 | 8 outlets5 | 6 outlets7 |
| VA rating | 600 VA12 | 700 VA13 | 1,500 VA3 | 1,500 VA4 | 1,500 VA5 | 1,500 VA7 |
| Runtime at full load | 3.2 min8 | 4 min8 | 5 min10 | 3 min4 | 3.1 min5 | 5.9 min (Workload: 1350W)7 |
| Total outlets | 7 outlets8 | 8 outlets8 | 6 outlets10 | 12 outlets4 | 8 outlets5 | 6 outlets7 |
| Output waveform | Not published | Not published | Pure sine3 | Simulated sine4 | Pure sine5 | Pure sine7 |
| UPS type | Not published | Not published | Online double conversion3 | Not published | Not published | Online double conversion7 |
| LCD panel | Not published | Not published | Not published | Not published | Not published | Yes14 |
| Form factor | Not published | Not published | Rack or tower (Tested configuration: Rack installation with rail kit SRTRK2 or SRTRK3, sold separately)3 | Tower4 | Rack mount6 | Tower7 |
| Rack height | Not published | Not published | Not published | Not published | 2 U6 | Not published |
| Input voltage | 120 V1 | Not published | 120 V10 | 120 V4 | 120 V5 | 120 V7 |
Find the right fit
6 products
APC BE600M1
- Output waveform
- Not published
- Form factor
- Not published
APC Back-UPS ES-BE700G
- Output waveform
- Not published
- Form factor
- Not published
How they compare
Scroll the table to see every product and specification.
| Specification | Our pickAPC BE600M1 | APC Back-UPS ES-BE700G | APC Smart-UPS SRT1500XLA | CyberPower CP1500AVRLCD3 | CyberPower CP1500PFCRM2U | Eaton 9SX1500 |
|---|---|---|---|---|---|---|
| Output capacity | 330 W1 | 405 W8 | 1,350 W3 | 900 W2 | 1,000 W6 | 1,350 W7 |
| Runtime at half load | 10 min8 | 13 min8 | Approx. 14 min (Workload: half load)11 | 12 min4 | 10.2 min5 | 16.5 min (Workload: 675W)7 |
| Battery-backed outlets | 5 outlets2 | 4 outlets9 | 6 outlets10 | 6 outlets2 | 8 outlets5 | 6 outlets7 |
| VA rating | 600 VA12 | 700 VA13 | 1,500 VA3 | 1,500 VA4 | 1,500 VA5 | 1,500 VA7 |
| Runtime at full load | 3.2 min8 | 4 min8 | 5 min10 | 3 min4 | 3.1 min5 | 5.9 min (Workload: 1350W)7 |
| Total outlets | 7 outlets8 | 8 outlets8 | 6 outlets10 | 12 outlets4 | 8 outlets5 | 6 outlets7 |
| Output waveform | Not published | Not published | Pure sine3 | Simulated sine4 | Pure sine5 | Pure sine7 |
| UPS type | Not published | Not published | Online double conversion3 | Not published | Not published | Online double conversion7 |
| LCD panel | Not published | Not published | Not published | Not published | Not published | Yes14 |
| Form factor | Not published | Not published | Rack or tower (Tested configuration: Rack installation with rail kit SRTRK2 or SRTRK3, sold separately)3 | Tower4 | Rack mount6 | Tower7 |
| Rack height | Not published | Not published | Not published | Not published | 2 U6 | Not published |
| Input voltage | 120 V1 | Not published | 120 V10 | 120 V4 | 120 V5 | 120 V7 |